ECOJOHN Logo  
1-866-ECOJOHN(326-5646)

WC Series    Toilet Waste Combustion System

The WC Series consist of a wide range of waste combustion systems (incinerators) in different sizes and fuel sources. All models in the WC series incinerate from a holding tank and operate with low flush toilets (0.8-1.2 gpf), regular flushing toilets (1.6 gpf), or vacuum toilets (0.2 gpf). WC5, WC32, and WC48 are all included in the WC series and use Propane, Diesel, or Natural Gas as fuel source depending on model and size. The waste combustion systems are ideal in any remote application where there is no access to septic or sewage system; in addition to new installations they can also be installed and connected to existing toilets. Thus in case there is an issue with failing or too costly sewage solutions one can add on a waste combustion system and eliminate the problems.

The incinerators along with low flush toilets provide ecological, economical, and logistical benefits. The WC models have the capability to incinerate between 1 to 5 gallons of waste per hour (depending on model). 

Models

WC5 – cabin, summer house, lower capacity usage areas
WC32 – smallest commercial incinerator – oil rigs, construction sites, camps, military, refugee camps, disaster relief, house boats
WC48 – largest commercial incinerator - oil rigs, construction sites, camps, military, refugee camps, disaster relief, house boats etc

Quick Facts
  • Incinerates black water from a waste holding tank
  • Provide ecological, economical, and logistical benefits
  • Eliminate costly and potential harmful issue associated with a standard pump out
  • The incinerators operate with low-flush water toilets, water and waste tanks.
  • No chemicals
  • Residential and commercial applications
  • Incinerator may be installed up to 300 ft from toilets
  • Withstand high usage and a severe environment
  • Easy control board with push buttons and display of statuses and messages
  • CSA and CE Approved
  • Custom size water and waste tanks available upon request
  • Easy access to clean out ash
  • 12VDC, 120 AC, or 240 AC
  • Diesel, propane, and natural gas
  • Works in cold climate and high elevation
  • System is mobile
  • Included 6” double wall vent pipe removes harmless resultants steam
  • No pump out or sewer required
  • Meets emission regulations
  • Interfaces with single or multiple toilets
  • Waterless urinals may be hooked up to system


  • Eliminate costly and potential harmful issue associated with a standard pump out
  • The incinerators operate with low-flush water toilets, water and waste tanks.
  • No chemicals
  • Residential and commercial applications
  • Incinerator may be installed up to 300 ft from toilets
  • Withstand high usage and a severe environment
  • Easy control board with push buttons and display of statuses and messages
  • CSA and CE Approved
  • Custom size water and waste tanks available upon request
  • Easy access to clean out ash
  • 12VDC, 120 AC, or 240 AC
  • Diesel, propane, and natural gas
  • Works in cold climate and high elevation
  • System is mobile
  • Included 6” double wall vent pipe removes harmless resultants steam
  • No pump out or sewer required
  • Meets emission regulations
  • Interfaces with single or multiple toilets
  • Waterless urinals may be hooked up to system

  • A low-flush toilet dissolves the waste with the built in macerator pump
  • Standard dual flush toilets or vacuum toilets may be used
  • Multiple toilets can be connected to one system
  • Showers, sinks, and urinals may also be connected to the system
  • Toilets can be used during the incineration
  • Moves black water into waste tank
  • Sensor signals level in tank
  • Automatically pump in waste water and commence incinerator when waste tank fills up
  • Pump and burn process repeats itself until waste tank is empty
  • Puts itself in standby when the waste tank is empty
  • May be set in Manual, Automatic Mode, or Timer Mode
  • May be set to commence incinerator at a certain time i.e. midnight
  • Easy operating control panel
  • Control panel displays multiple functions i.e. temperature, levels in tanks

Installation

The components in the system are plug-and-play which makes the installation process uncomplicated. Below are some basic facts about the installation:

  • The incinerator must be placed above ground
  • Waste holding tank and incinerator can be placed up to 300 ft away from toilet
  • Incinerator and waste tank must be installed within 10 ft of each other unless the incinerator is installed below the waste tank i.e. crawl space.
  • The incinerator can be installed up to 5 ft above the waste tank
  • Incinerator must be installed inside a weather proof building/structure
  • Incinerator requires 5 inches clearance from any wall
  • 1 ft clearance is recommended in front of the clean out door and burner door on the incinerator
  • Should not be installed or operated in an area where there is a risk of an accumulation of flammable vapors or dust
  • The chimney has to be a minimum of 7 ft long
  • The chimney can be vented out through the side wall using elbows

Please consult with ECOJOHN® for specific installations.

Download specific installation instructions in the download section.    

MAINTENANCE AND CLEANING

The waste combustion system is a very reliable in operation and maintenance free if operated as per the manufacturer’s instructions. The maintenance can easily be done by one person and consists of filling up water in water tank (unless a pressurized water system is used), filling up fuel, and periodically empty ashes from burn chamber.

TECHNICAL INFO
WC5
WC32 WC48
Fuel
Propane
Propane Propane
Natural Gas Natural Gas
Diesel Diesel
Operating Voltage
12V DC
12V DC 12V DC
120V AC 120V AC 120V AC
  220V AC 220V AC
Dimension
25" x 16" x 27"
50" x 28.5" x 35" 62" x 28.5" x 35"
Weight
122 lbs
250 lbs 350 lbs
Burning Capacity
1 gal/hr
3 gal/hr 6 gal/hr
Fuel Consumption Propane
0.5 lbs/hr
1.50 lbs/hr 3 lbs/hr
  Natural Gas
N/A
0.60 therm/hr 1.40 therm/hr
  Diesel
N/A
0.6 gal/hr 0.9 gal/hr
Operating Temperature
32F to 140F
32F to 140F 32F to 140F


SAFETY
The WC series are very safe when assembled and used properly. In order to provide a high quality system, we have chosen to only use top quality materials that are made to withstand high usage and a severe environment. All WC models go through several meticulous testing procedures to monitor quality control.


Company  l  Sitemap  l  Privacy & Security  l  Contact Us  l  Send Feedback